HVAC professional with solid track record in system installation, maintenance, and repair. Known for reliability and adaptability, contributing to team success and delivering high-quality results. Skilled in troubleshooting and optimizing HVAC systems to meet client needs. Committed to maintaining high standards and achieving project goals.
Solenoid Valves -Migration Prevention.
TXV & Fixed Orifice - Measures Freon availabilty to enter the system.
Low Ambient Units - Made to operate in low temps.
Fan coil Units ( FUC )- Provides Heating or Cooling without ductwork.
A2L Refrigerant Certified-a type of refrigerant classified by ASHRAE Standard 34 as having lower flammability and toxicity compared to other refrigerants, while still offering similar operating characteristics to legacy refrigerants. They are often used as alternatives to higher Global Warming Potential (GWP) refrigerants like ( HFCS
Glycol - A chemical which is used like a Ainti-frezze but less toxic.
VAVS - Control Air Flow.
CAVS - Gives Constant Air Flow.
Hepa Filtration- Specificaly ( CamFill ) Environments with high levels of pollution, dust, or allergens will require more frequent filter changes.
Pre Filters - regular cleaning or replacement of this filter can extend the lifespan of the HEPA filter.
PSC MOTORS - Split Capcitor Motors.
EMC MOTORS - Electronically Commulated Motors.
BIOMECTRIC DAMPERS - Helps reduce pressure build up.
MINI SPLIT SYSTEMS - Ductless A/C Systems.
R32 & R454B - I have certified training in these refrigerants aiming to reduce global warming potential (GWP) and improve energy efficiency.
LASER ALIGNMENET TOOLS - Made for percise positioning.
ELECTRIC POWERED LIFTS
VMUS - Used in modulating premixed appliances ( gas burners) ( boilers) ( AHU's).
CHILLERS - Closed loop systems which removes heat from a liquid & circulates cool water using freon.
VFD - Motor controlled adjust speeds by using its frequency & voltage often called a ( Frequency Drive ).
CIRCUIT SETTERS - Measures flow through valves creating a balanced flow and enables isolation.
ISOLATION VALVES - Being able to isolate the equipment for service.
CIRCULATING PUMPS - Ensures Circulations transfers heat using impellar power by electric.
ECONOMIZER - uses cooler outdoor air to provide cooling when the outdoor conditions are favorable, thus reducing the workload and energy.
Performed troubleshooting on HVAC systems to determine root cause of issues.
EPA CERTIFIED - Section 608 certification, s a credential issued by the Environmental Protection Agency (EPA) to individuals who handle refrigerants in HVACR equipment
AL2 CERTIFIED - ensures technicians are properly trained to handle A2L refrigerants safely, which are considered mildly flammable.